Impactful Findings from Medical Imaging Research

Dive into a collection of short summaries of recent medical imaging studies that shed light on hot topics such as structured reporting, texture analysis, radiomics, or novel imaging biomarkers. Identify the role mint Lesion™ played in these studies and contact us if you have any questions about our software platform.

Here you will find a detailed list of scientific publications in which mint Lesion™ has had a significant impact:

Explore the publications

Diagram that shows reduced reading times for the mint Lesion™ approach at both follow-ups.

UKE Hamburg: Study Shows that Software-Assisted Assessments Enhance iRECIST Evaluation

This research study [1] aimed to compare the feasibility and reliability of manual versus software-assisted assessments of computed tomography (CT) scans according to iRECIST (immune Response Evaluation Criteria in Solid Tumors) in oncological patients undergoing immune-based treatment. The study involved evaluating CT scans of 30 tumor patients at baseline (BL) and two follow-ups (FU1 and FU2), resulting in 360 tumor assessments. After image interpretation, tumor burden and response status were calculated manually or with software assistance. 

mint Lesion™ was employed for the software-assisted assessment. Target and non-target lesions were initially annotated within the software and assessed using dedicated tools. The software facilitated adherence to the iRECIST guidelines by offering assessment guidance and highlighting deviations or errors (such as one-dimensional measurement of lymph nodes or an excessive number of lesions).

The reading time, error rate, and inter-reader agreement were compared between the manual and software-assisted approaches, with the following findings:

  • Reading Time: The study found significantly shorter reading times for software-assisted assessments compared to manual assessments at both follow-ups. The median reading time at FU1 was 2.5 minutes for the software-assisted assessment and 4 minutes for the manual assessment, and for FU2, it was 2 minutes vs. 3.75 minutes, respectively.
  • Error Rate: Software-assisted assessments demonstrated lower error rates, with 0% errors for software-assisted assessments compared to 3.3% for manual assessments at FU1 and 1.7% versus 10% at FU2. 
  • Inter-Reader Agreement: The study demonstrated good to excellent inter-reader agreement for both manual and software-assisted assessments. However, the agreement was higher for software-assisted assessments, particularly at the second follow-up. The manual assessments' intraclass correlation coefficient (ICC) was 0.91 at FU1 and 0.75 at FU2. For software-assisted assessments, the ICC was 0.93 at FU1 and 0.86 at FU2.

"Our results reveal that software-assisted iRECIST readings can be performed with (I) less time effort, (II) fewer incorrect response assessments, and (III) a higher inter-reader agreement compared to manual approaches," concluded the researchers. 

The study's findings demonstrate that utilizing software-assisted solutions is preferable over manual approaches for optimal oncological response evaluation. This is particularly relevant for iRECIST assessments, where accurate evaluation necessitates a solid understanding of the fundamental rules and a comprehensive review of prior examinations, notably streamlined by software assistance.

Read the original publication here.

[1] Ristow I, Well L, Wiese NJ, Warncke M, Tintelnot J, Karimzadeh A, Koehler D, Adam G, Bannas P, Sauer M. Tumor Response Evaluation Using iRECIST: Feasibility and Reliability of Manual Versus Software-Assisted Assessments. Cancers. 2024

Related Resources

Related Resources

Mint Medical and Agfa HealthCare announce seamless integration of mint Lesion and ORBIS RIS at RSNA 2018

Heidelberg, Bonn, GER - At this year’s Radiological Society of North America (RSNA) Annual Meeting 2018, Agfa HealthCare and Mint Medical will…

mint PI-RADS V2 report as the standard for communication with urologists - Interview with PD Dr. Röthke

Since the beginning of 2017, all PI-RADS v2 reads are exclusively performed with mint Lesion™ by PD Dr. Matthias Röthke, Chief Medical Officer at…

Pancreas staging in clinical routine at University Hospital Innsbruck - Interview with PD Dr. Widmann

The University Hospital in Innsbruck, Austria, has been using mint Lesion™ since mid-2015 with the initial focus on clinical trials in order to…