jump to content jump to footer
Radiologist reviewing a glioma MRI case in mint Lesion, with AI-based brain tumor segmentation from Snke (in development)

Consistent Glioma MRI Reporting with mint Lesion

In neuro-oncology, imaging assessments directly shape treatment decisions. For example, under RANO 2.0, whether a follow-up MRI is classified as progression can determine if a patient continues on therapy or moves to a different line of treatment. The reliability of that decision depends on consistency: across readers, across time points, and across evolving response criteria. mint Lesion is designed to make glioma MRI reporting structured and reproducible, so referring clinicians can rely on it from first detection through long-term follow-up and on to the tumor board.

The challenge: inconsistency in glioma assessment

Published data points to several sources of inconsistency in glioma MRI assessment. Reader variability of around 22% has been reported for measurements of the same tumor, and readers agree poorly on segmentation after resection¹. Two-dimensional measurements are associated with a false-positive progression rate of around 14%².

Free-text reports add a further gap, as they do not reliably capture every diagnostic item a complete assessment requires. Because RANO 2.0 progression rules drive treatment changes, applying them correctly and consistently is essential.

 

The Response: consistency by design

mint Lesion addresses these challenges with an approach built on structured reporting, embedded response criteria and reusable data.

Structured reporting and longitudinal tracking

Standardized descriptors and a structured workflow support reproducible assessment. Each measured lesion is followed across examinations, which keeps evaluations consistent from baseline through every follow-up.

Embedded RANO 2.0 and response automation

mint Lesion automates response classification and applies criteria consistently. Parameters can be configured to match the study protocol. Tumor burden is calculated as SPPD (2D) and SOV (volumetric), grouped by lesion type and measurement method. Confirmation-scan logic runs automatically, using RANO 2.0 defaults or custom study settings.

For a closer look at the configuration options, tumor burden tracking and confirmation-scan logic, read our article Implementing RANO 2.0 for Neuro-Oncology Clinical Trials in mint Lesion.

Structured data for downstream use

The data export combines radiomics, annotated images and guideline context. It runs automatically and is ready for statistical analysis, while configurable eCRFs capture non-imaging parameters. Annotated datasets stay linked over time. Supporting DICOM-SEG export and FHIR interoperability, mint Lesion can integrate with radiotherapy planning and the wider clinical IT environment.

 

Looking ahead: anatomical context and AI-based segmentation

Further capabilities are currently in development*. The Anatomical Patient Model (APM) provides anatomy segmentation, anatomical landmark localization and tumor segmentation for the brain. Its “Anatomy GPS” displays anatomical labels wherever the user clicks and links questionnaires to images, so reports remain traceable.

Building on the APM, AI-based segmentation of brain tumors will provide both the tumor core on T1-weighted MRI and the whole tumor on T2/FLAIR. The aim is to reduce variability between readers and to deliver standardized tumor segmentations as the basis for 2D and volumetric measurements, together with the anatomical context of each tumor.

 

Reproducible glioma reporting 

With structured reporting, embedded RANO 2.0 logic and data ready for downstream use, mint Lesion supports a consistent standard across readers, time points and changing criteria.

* Features in development are not yet commercially available.

 

References

¹van der Loo, I., Tareco Bucho, T. M., Hanley, J. A. et al. Measurement variability of radiologists when measuring brain tumors, Eur. J. Radiol. (2025). https://doi.org/10.1016/j.ejrad.2024.111874

²Provenzale, J. M., Ison, C., DeLong, D. Bidimensional measurements in brain tumors: assessment of interobserver variability, Am. J. Roentgenol. (2009). https://doi.org/10.2214/AJR.09.2615

Research poster presentation on standardized tumor response assessments using mint Lesion at the NCCN Annual Conference 2026
Presentation of a research poster by Memorial Sloan Kettering Cancer Center on the use of mint Lesion for structured tumor response assessments and clinical research workflows.
NCCN 2026: Memorial Sloan Kettering Cancer Center Presents Research on Structured Tumor Response Assessments with mint Lesion
Big congratulations to Steven Philemond and Alison Chiaramonte of Memorial Sloan Kettering Cancer Center for presenting their research poster “Use of…
Read more
Radiologist using mint Lesion for structured reporting and AI-supported workflows in lung cancer screening
How radiology practices can participate in lung cancer screening in Germany with mint Lesion through structured reporting, AI-supported workflows, and integrated collaboration with second-reading centers.
How Radiology Practices Can Participate in Germany’s Lung Cancer Screening Program with mint Lesion
New opportunities - but also economic uncertainty With the launch of lung cancer screening (LCS) in Germany, radiology practices are facing a new…
Read more
Hospital staff using mint Lesion for interoperable workflows and data management in lung cancer screening
How mint Lesion supports hospitals and screening centers with interoperable infrastructure, AI integration, data management, and scalable workflows for lung cancer screening.
Lung Cancer Screening in Germany: How mint Lesion Supports Hospitals with Infrastructure, Integration, and Scalability
Screening as a Strategic Challenge With the launch of the national lung cancer screening program in 2026, hospitals and screening centers across…
Read more
scroll-top