jump to content jump to footer

UKE Hamburg: Study Shows that Software-Assisted Assessments Enhance iRECIST Evaluation

This research study [1] aimed to compare the feasibility and reliability of manual versus software-assisted assessments of computed tomography (CT) scans according to iRECIST (immune Response Evaluation Criteria in Solid Tumors) in oncological patients undergoing immune-based treatment. The study involved evaluating CT scans of 30 tumor patients at baseline (BL) and two follow-ups (FU1 and FU2), resulting in 360 tumor assessments. After image interpretation, tumor burden and response status were calculated manually or with software assistance. 

mint Lesion™ was employed for the software-assisted assessment. Target and non-target lesions were initially annotated within the software and assessed using dedicated tools. The software facilitated adherence to the iRECIST guidelines by offering assessment guidance and highlighting deviations or errors (such as one-dimensional measurement of lymph nodes or an excessive number of lesions).

The reading time, error rate, and inter-reader agreement were compared between the manual and software-assisted approaches, with the following findings:

  • Reading Time: The study found significantly shorter reading times for software-assisted assessments compared to manual assessments at both follow-ups. The median reading time at FU1 was 2.5 minutes for the software-assisted assessment and 4 minutes for the manual assessment, and for FU2, it was 2 minutes vs. 3.75 minutes, respectively.
  • Error Rate: Software-assisted assessments demonstrated lower error rates, with 0% errors for software-assisted assessments compared to 3.3% for manual assessments at FU1 and 1.7% versus 10% at FU2.
  • Inter-Reader Agreement: The study demonstrated good to excellent inter-reader agreement for both manual and software-assisted assessments. However, the agreement was higher for software-assisted assessments, particularly at the second follow-up. The manual assessments' intraclass correlation coefficient (ICC) was 0.91 at FU1 and 0.75 at FU2. For software-assisted assessments, the ICC was 0.93 at FU1 and 0.86 at FU2.

"Our results reveal that software-assisted iRECIST readings can be performed with (I) less time effort, (II) fewer incorrect response assessments, and (III) a higher inter-reader agreement compared to manual approaches," concluded the researchers. 

The study's findings demonstrate that utilizing software-assisted solutions is preferable over manual approaches for optimal oncological response evaluation. This is particularly relevant for iRECIST assessments, where accurate evaluation necessitates a solid understanding of the fundamental rules and a comprehensive review of prior examinations, notably streamlined by software assistance.

Read the original publication here.

[1] Ristow I, Well L, Wiese NJ, Warncke M, Tintelnot J, Karimzadeh A, Koehler D, Adam G, Bannas P, Sauer M. Tumor Response Evaluation Using iRECIST: Feasibility and Reliability of Manual Versus Software-Assisted Assessments. Cancers. 2024

Mint Medical and Coreline teams coming together to announce partnership
Mint Medical and Coreline Soft integrate AVIEW into mint Lesion to support AI-enabled workflows for structured reporting, Lung-RADS assessment, and longitudinal nodule management in lung cancer screening.
Coreline Soft and Mint Medical Announce Partnership to Advance AI-Enabled Lung Cancer Screening
Coreline Soft and Mint Medical today announced a partnership to advance AI-enabled lung cancer screening, following more than six months of technical…
Read more
Integrated prostate cancer workflow connecting radiology, urology, and pathology through structured reporting, MRI-guided biopsy, longitudinal follow-up, and AI-supported analysis.
mint Lesion supports an end-to-end prostate cancer workflow by connecting radiology, urology, and pathology within a unified digital environment. The platform enables structured mpMRI reporting, MRI/ultrasound fusion biopsy workflows, FHIR-based interoperability, active surveillance, and AI-supported quantification of metastatic disease.
Be Central to the Insight: A Structured, Data-Driven Approach to the End-to-End Prostate Pathway
Digital Integration for Multidisciplinary Teams  In the complex journey of prostate cancer diagnostics, the data contributed by every department is…
Read more
Research poster presentation on standardized tumor response assessments using mint Lesion at the NCCN Annual Conference 2026
Presentation of a research poster by Memorial Sloan Kettering Cancer Center on the use of mint Lesion for structured tumor response assessments and clinical research workflows.
NCCN 2026: Memorial Sloan Kettering Cancer Center Presents Research on Structured Tumor Response Assessments with mint Lesion
Big congratulations to Steven Philemond and Alison Chiaramonte of Memorial Sloan Kettering Cancer Center for presenting their research poster “Use of…
Read more
scroll-top